IEC 61010-2-020:2026 defines particular safety requirements for electrically powered laboratory centrifuges. As Part 2-020 of the IEC 61010 series, it amends and supplements the general standard so that the combined text applies specifically to centrifuge equipment. This overview summarizes the record data and the official scope, and outlines how testing and quality teams typically work with such a document in practice.

Standard Information

IEC 61010-2-020:2026 is a product safety publication for laboratory centrifuges. It forms part of the IEC 61010 family, which governs electrical equipment for measurement, control, and laboratory use, and it must be read together with the base standard of that family. The document has the status of a group safety publication under IEC Guide 104. - Designation: IEC 61010-2-020:2026
- Full title: Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-020: Particular requirements for laboratory centrifuges
- Status: Current
- Publication date: 2026-09-02
- ICS classification: 71, 71.040, 71.040.10
- Technical committee: TC 66

Scope and Application

The standard applies to electrically powered laboratory centrifuges. It is possible that all or part of the equipment falls within the scope of one or more other Part 2 standards of IEC 61010 as well as within the scope of this document. In that case, the requirements of those other Part 2 standards also apply, so a given machine may need to satisfy several particular requirements documents at once. This fourth edition cancels and replaces the third edition published in 2016, and it constitutes a technical revision. The significant technical change with respect to the previous edition is alignment with changes introduced by Amendment 1:2016 of IEC 61010-1:2010. The document is intended to be used in conjunction with the latest edition of IEC 61010-1. It was established on the basis of the third edition (2010) of that standard and its Amendment 1 (2016), referred to as Part 1. Where a particular subclause of IEC 61010-1 is not mentioned here, that subclause applies as far as is reasonable. Where the text states "addition", "modification" or "replacement", the corresponding requirement in Part 1 shall be adapted accordingly.

Products and Materials Covered

The products in scope are laboratory centrifuges that operate on electrical power. Within the ICS classification, the standard sits under chemistry (71), analytical chemistry (71.040), and chemical laboratories and laboratory equipment (71.040.10), which corresponds to the laboratory instrument sector rather than industrial process machinery or medical devices. Because overlapping scopes are expressly contemplated, an item of equipment may simultaneously be covered by this Part 2-020 and by other Part 2 documents of the same series. Procurement specialists should therefore identify every applicable Part 2 document for a given centrifuge configuration before compiling a compliance file.

Testing and Compliance Considerations

For a particular requirements document of this kind, the usual workflow is a type test against the combined text: the base standard first, then each "addition", "modification" or "replacement" clause that changes the corresponding requirement. An accredited laboratory performs the evaluation, records the clause-by-clause results, and issues a report that references both documents and the edition used. Acceptance verification typically follows in the buyer's laboratory, confirming that the delivered configuration matches the tested sample in rating, construction, and markings. Documentation then supports traceability throughout the equipment life cycle. Retest triggers include design changes, firmware updates affecting safety functions, component substitutions, or a revised edition of either the base standard or this Part 2-020. When a newer edition appears, quality managers assess whether existing reports remain defensible or whether delta testing is warranted; disputes over results are normally resolved by joint review of the test setup against the clause wording rather than by unilateral retesting.

Related Standards and Series Context

The designation itself conveys the structure. IEC 61010 is the series number for safety requirements covering electrical equipment for measurement, control, and laboratory use. The suffix 2-020 marks a Part 2 document, meaning it supplies particular requirements for a defined equipment category, here laboratory centrifuges. The year 2026 identifies the edition. A Part 2 document never stands alone. It supplements or modifies the general requirements of the base standard, so users must always work with the latest edition of that base document plus the particular part. In this sense the fourth edition (2026) replaces the third edition (2016) for centrifuge applications, and the "-2-020" numbering will persist across future editions of the same subject.

Quick Answers

Frequently Asked Questions

01

How is a submission for IEC 61010-2-020:2026 centrifuge testing typically handled?

Submissions begin with confirming that the equipment falls within the scope and application of IEC 61010-2-020:2026, followed by documenting the products and materials covered. Clear communication with the testing body about compliance considerations ensures the correct test plan and evaluation path are agreed before work starts.

02

What

factors affect the cost of testing under IEC 61010-2-020:2026?
Costs depend mainly on the scope and application of the standard for the specific equipment, the range of products and materials covered, and the extent of testing and compliance considerations required. Whether evaluation also involves related standards within the IEC 61010 series can further influence the overall effort and pricing.

03

How are retests and data disputes handled for IEC 61010-2-020:2026 evaluations?

Retesting is usually scoped by reviewing the original testing and compliance considerations against the disputed results, ensuring the products and materials covered are re-evaluated consistently with the standard's requirements. Where questions remain, the related standards and series context helps clarify which criteria apply and supports resolution between the parties.

← Previous Article Seat belt testing
Next Article → Security door testing

Ready to Discuss Your Testing Needs?

Contact our team for a customized quote and expert consultation on your IEC 61010-2-020:2026 – Safety requirements for electrical equipment for measurement, control, and la testing requirements.

Contact Our Team