EU CE marking for electric storage heaters requires conformity with the Low Voltage Directive, the Electromagnetic Compatibility Directive, ecodesign and energy labelling regulations, and, where wireless or remote control functions exist, the Radio Equipment Directive. Verification rests on type testing against harmonized safety and performance standards. The manufacturer consolidates results in technical documentation and signs a Declaration of Conformity.

scope and directives

CE marking for electric storage heaters draws on several directives rather than a single instrument. The Low Voltage Directive (2014/35/EU) covers electrical safety for appliances operating within its voltage range. The Electromagnetic Compatibility Directive (2014/30/EU) addresses emission and immunity behaviour in residential environments. Energy-related requirements fall under Regulation (EU) 2015/1185 for local space heaters and Regulation (EU) 2015/1186 on energy labelling. Both apply to storage heaters sold in the EU. These ecodesign rules set information requirements and efficiency-related declarations that must be verified by measurement. If the heater includes a room-temperature sensor with wireless communication or an app-based charge controller, the Radio Equipment Directive (2014/53/EU) also applies. The manufacturer consolidates the results in technical documentation and signs a Declaration of Conformity, a step covered separately in guidance on making a Declaration of Conformity for CE marking. These regulatory dimensions also intersect with the compliance logic used in broader energy storage programmes.

Applicable harmonized standards (EN 60335-2-53, EN 50564)

The principal safety standard is EN 60335-2-53. It is a particular requirement within the EN 60335-1 household and similar electrical appliances series, specific to electric storage heaters. It modifies and supplements the general clauses of Part 1 with construction, marking, and abnormal-operation requirements. These suit a heat-storing mass that remains hot long after disconnection. Part 1 clauses concerning creepage distances, clearances, and endurance of heating elements are read together with the particular requirements. On the energy side, EN 50564 specifies measurement of low electrical power consumed by household and office equipment. It is applied to determine off-mode and standby consumption declared under the ecodesign regulation. Supporting measurement methods for heat output and control accuracy come from harmonized performance standards for storage heaters. The standard set differs from those used for resistive plug-in heaters, and from appliance-specific parts applied in Electric Iron Testing or electric blanket testing. However, the structure of particular requirements under EN 60335-1 is common to all such appliances.

Test items and sample preparation

A typical test programme includes marking and instructions review, input power and current at rated voltage, heating performance and charge retention, temperature rise of the core and enclosure, surface temperature limits, humidity resistance of the insulation system, electric strength, leakage current at operating temperature, abnormal operation such as blocked charge control, stability and mechanical strength, and EMC emission plus immunity. Sample preparation matters for reproducibility. Heaters must be installed as in normal use, mounted on a wall of non-combustible material representative of intended installation, and conditioned at rated voltage and frequency until thermal steady state. The storage core should be fully discharged before charging tests begin. Instrumentation includes thermocouples attached to the core, fan motor windings, and accessible surfaces, a calibrated power analyser, and a climate-controlled test room. Samples intended for electric bicycle testing or other programmes are run in separate schedules. Heater tests require long thermal cycling that occupies chambers for extended periods.

Test methods — leakage, heating performance, EMC

Leakage current is measured at operating temperature with the appliance supplied at rated voltage. This follows the measuring circuit prescribed in EN 60335-1, with the storage core at steady hot condition. Electric strength is then verified by applying the standard test voltage between live parts and accessible metal parts. Heating performance testing charges the core for the declared charge period at declared input. Heat output is then measured over the discharge period in a calibrated calorimetric room or by the enthalpy method. The test records output curves, charge retention, and thermostat or charge-control accuracy under declared occupancy patterns. Compliance with EN 50564 standby measurement is performed after functional testing, using the power analyser in low-power ranges. EMC testing follows the generic household-appliance emission standards, conducted and radiated. Immunity tests cover electrostatic discharge, fast transients, surge, and RF fields. Storage heaters with electronic charge controllers are classified as category equipment with continuous control. Guard against thermocouple detachment on the core, which invalidates temperature data.

Acceptance criteria and test report

Acceptance is judged against the limit values in the applied standards. Measured leakage current and electric strength results must fall within the limits of EN 60335-1 as modified by EN 60335-2-53. Temperatures of the core, windings, and accessible surfaces must not exceed the limits assigned to their insulating material class and touch categories. Abnormal operation must not release flame, molten metal, or hazardous live parts. Declared heat output, efficiency-related figures, and standby consumption must match the values filed under the ecodesign regulations. Emission levels must sit below the class-B residential limits. The test report should identify the sample and its ratings, state installation conditions, and list instruments and their calibration status. It should present measurement tables and thermal curves, note any deviations, and record a conformity statement per clause. Reports of this kind are used for technical-file retention, market-surveillance response, and import documentation. This mirrors practice in battery and energy storage testing and certification solutions.

Application scenarios and certification process

The certification route begins with design review against the standard list. Type testing then follows at an accredited laboratory on representative samples. Where a voluntary certification scheme is chosen beyond the mandatory CE self-declaration, a follow-up factory inspection usually takes place. Typical scenarios include new-model market entry into the EU, redesigns affecting the heating core or charge electronics, private-label importers verifying supplier claims, and responses to market-surveillance authority requests. A manufacturer collects the test reports, risk assessment, and declarations into the technical file. The manufacturer then signs the EU Declaration of Conformity and affixes CE marking, supported where applicable by energy labelling data sheets. Periodic retesting is advisable when components such as charge controllers, insulation materials, or surface coatings change. This concern is reinforced by evolving chemical restrictions such as the EU ban on bisphenol A in food contact materials testing, which illustrates how material rules can force re-evaluation of appliance components. Maintained files shorten audits and customs queries.

Quick Answers

Frequently Asked Questions

01

How do I choose the right approach to EU CE marking requirements for electric storage heaters?

Method selection depends on the product's design and intended use. Review the scope of the applicable directives. Confirm which harmonized standards such as EN 60335-2-53 and EN 50564 apply. Then follow the certification process for the relevant application scenario. Applicability differs between heater types and markets.

02

What is the judgment basis for EU CE marking requirements for electric storage heaters?

Acceptance is based on the limit values and criteria set out in the applicable harmonized standards and directives. Test results for leakage, heating performance, and EMC must be evaluated against these references. The conclusions are documented in the test report supporting CE conformity.

03

Which products fall within the EU CE marking requirements for electric storage heaters?

The material scope covers electric storage heaters intended for the EU market, as defined by the directives and standards discussed under scope. Products outside that defined scope, or heater types not matching the applicable standards, require separate assessment to confirm whether CE marking obligations apply.