12 Instruments Available
51

gear oil tests Testing

2026-11-13

Gear oil tests verify viscosity grade and viscosity index, additive and wear elements by ICP-OES, oxidation by FT-IR, extreme-pressure and anti-wear capability by four-ball and FZG methods, plus water and particle contamination per ISO 4406. Sampling

→
52

residual breaking load test rope Testing

2026-11-13

Residual breaking load testing measures the tensile strength a rope retains after service, damage, or ageing. A conditioned specimen is pulled to rupture in a calibrated tensile machine, and the maximum force is compared with the original minimum bre

→
53

metallographic analysis and ahemical analysis Testing

2026-11-13

Metallographic and chemical analysis testing characterizes metals by combining microstructure examination — optical microscopy, microhardness and SEM — with quantitative elemental methods such as OES, ICP-MS and XRF. The workflow runs from sampling a

→
54

testing frequency for elastic ropes

2026-11-13

Testing frequency for elastic ropes is set by risk and process stability: lot-by-lot verification of breaking force and elongation for routine control, one-time type testing for new designs, and scheduled in-service testing where failure consequences

→
55

hydroxyapatite coating amorphous phase crystallinity iso

2026-11-13

Hydroxyapatite coating amorphous phase crystallinity is assessed under ISO 13779 primarily by X-ray diffraction, with FTIR band indices as a cross-check. Specimens must remain flat and uncontaminated; crystallinity is calculated from crystalline-to-t

→
56

dep in plastic gcms test Testing

2026-11-13

DEHP in plastic GC-MS testing quantifies the phthalate plasticizer DEHP in polymers by solvent extraction followed by gas chromatography with mass spectrometric confirmation. The method covers sample homogenization, extraction, cleanup, selected-ion

→
57

breaking wire rope lab test Testing

2026-11-13

A breaking wire rope lab test loads a seized specimen axially on a vertical or horizontal tensile machine until fracture, recording maximum force, elongation and fracture appearance. Results are judged against the specified minimum breaking force und

→
58

proof test shackle Testing

2026-11-12

Proof test shackle testing applies a specified load, typically a multiple of the working load limit, to verify that the shackle body and pin sustain loading without permanent deformation or cracking. The procedure covers sample mounting, gradual load

→
59

Measuring Hydroxyapatite Crystallinity by XRD for ISO 13779

2026-11-12

XRD crystallinity testing per ISO 13779 quantifies the crystalline fraction of hydroxyapatite coatings on medical implants. After careful powder or coupon preparation, a copper K-alpha diffractometer scan is processed by integrating crystalline peak

→
60

Hydroxyapatite Coating Adhesion Testing: ASTM F1147 Tensile

2026-11-12

ASTM F1147 tensile testing measures the pull-off adhesion strength of hydroxyapatite coatings on implant substrates. Coated coupons are bonded to cylindrical dummies with epoxy, pulled perpendicular to the surface in a universal testing machine, and

→
61

Hydroxyapatite Coating Testing to ISO 13779: Composition

2026-11-12

Hydroxyapatite coating composition testing to ISO 13779 combines XRD phase identification, FTIR functional-group verification, and ICP-OES quantification of calcium and phosphorus to confirm the Ca/P molar ratio against the stoichiometric 1.67 value.

→
62

ISO 13779 Hydroxyapatite Coating Testing: Laboratory

2026-11-12

ISO 13779 hydroxyapatite coating testing evaluates plasma-sprayed implant coatings through witness coupons, cross-sectional and XRF thickness measurement, tensile pull-off adhesion, XRD and FTIR crystallinity/phase analysis, and ICP-OES or XRF Ca/P r

→
63

SEM Image Analysis in the Laboratory: Particle Sizing

2026-11-12

SEM image analysis measures particle size directly from calibrated electron microscope images, resolving individual particles from nanometers to tens of micrometers. After dispersion, coating, and image acquisition, software segments particles and re

→
64

How Much Does SEM Testing Cost? Pricing Factors for

2026-11-12

SEM testing cost is driven mainly by sample preparation complexity, the number of items or fields imaged, the imaging mode selected, and turnaround. Conductive metals need minimal preparation, while non-conductive or cross-sectioned samples incur hig

→
65

SEM-EDS Testing Explained: Element Mapping and Point

2026-11-12

SEM-EDS testing identifies elements on solid surfaces at micrometre scale by detecting characteristic X-rays excited by the electron beam. Point analysis quantifies composition at selected features; element mapping shows spatial distribution of phase

→
66

SEM Analysis Services in China: Capabilities, Sample

2026-11-12

SEM analysis services in China cover surface morphology imaging, cross-sectional structure examination, and coupled elemental analysis by EDS and crystallographic analysis by EBSD. Field-emission instruments deliver nanometer-scale resolution; sample

→
67

SEM Testing Services in China: How to Choose a Scanning

2026-11-12

SEM testing services in China cover surface morphology imaging, fracture analysis, coating inspection, and elemental identification. Choose a scanning electron microscope laboratory by verifying instrument type, imaging modes (SE/BSE), preparation ca

→
68

Milk Shelf Life Testing Protocols: Accelerated and

2026-11-11

Milk shelf life testing protocols combine real-time storage studies with accelerated temperature-stress modeling. Replicate units are sampled on fixed schedules for plate count and PCR enumeration, HPLC and GC-MS analysis of freshness markers such as

→
69

Milk Antibiotic Residue Testing: Maximum Residue Limits and

2026-11-11

Milk antibiotic residue testing detects beta-lactams, tetracyclines, sulfonamides, macrolides and aminoglycosides against jurisdiction-specific maximum residue limits. The workflow runs from representative sampling through ELISA and microbial inhibit

→
70

Choosing a Dairy Product Quality Testing Lab

2026-11-11

Choose a dairy product quality testing lab by verifying accredited scope covering your exact matrix and analytes, confirming validated methods (HPLC, GC-MS, ELISA, PCR, spectrophotometry) with adequate detection limits, reviewing cold-chain sample ha

→
71

Raw Milk Microbiological Testing: Total Plate Count

2026-11-11

Raw milk total plate count testing measures viable aerobic mesophilic bacteria in CFU/mL using plate count agar and serial dilution, via pour-plate or spread-plate procedures with incubation and colony counting. Method sensitivity, repeatability, and

→
72

Milk Processing Testing: Complete Laboratory Solutions from

2026-11-11

Milk processing testing combines microbiological culture and PCR pathogen detection with HPLC and GC-MS residue analysis, supported by disciplined sampling from raw reception to filling lines. Method performance is verified through detection limits,

→
73

Ellipsometry for Thin Film and Resist Thickness: Principles

2026-11-11

Ellipsometry measures thin film and resist thickness by analyzing the polarization change of reflected light. Spectroscopic measurement combined with optical model fitting yields sub-nanometer thickness sensitivity together with refractive index and

→
74

Photoresist Thickness Uniformity Testing: Wafer Mapping

2026-11-11

Photoresist thickness uniformity testing maps resist thickness across the wafer using reflectometric spectrophotometry or stylus profilometry. Preparation requires a baked, clean, equilibrated wafer and a fixed polar site grid with edge exclusion. Re

→
75

Building a Photoresist Spin Curve: Thickness vs Spin Speed

2026-11-11

A photoresist spin curve relates coated film thickness to spin speed. Build it by cleaning substrates consistently, spin-coating identical samples at stepped speeds with all other parameters fixed, measuring thickness by stylus profilometry or ellips

→