How to Measure Photoresist Thickness After Spin Coating
2026-11-11Photoresist thickness after spin coating is measured on soft-baked films using stylus profilometry, spectroscopic ellipsometry, or spectral reflectometry, with 9- to 49-point wafer maps excluding the edge bead. Ellipsometry also yields refractive ind
Stylus Profilometry vs Ellipsometry vs SEM: Comparing
2026-11-11Stylus profilometry measures step height mechanically and directly, ellipsometry derives transparent-film thickness optically through model fitting, and SEM delivers nanometer-scale cross-sectional imaging of opaque or multilayer stacks. Selection de
Measuring the Thermal Expansion Coefficient of Borosilicate
2026-11-10The thermal expansion coefficient of borosilicate glass is measured by push-rod dilatometry per ISO 7991 or ASTM E228. A ground, annealed specimen is heated at a controlled rate while a displacement sensor records length change, corrected against a r
Thermal Shock Resistance Testing of Borosilicate Glass 3.3
2026-11-10Thermal shock resistance testing of borosilicate glass 3.3 verifies that glassware endures a declared temperature differential without cracking. Conditioned specimens are quenched from a hot water bath into a cold bath, inspected visually and with dy
Hydrostatic Pressure Testing of Borosilicate Glass
2026-11-10Hydrostatic pressure testing of borosilicate glass determines burst pressure and proof-pressure hold performance under controlled hydraulic loading, following ASTM C147 or ISO 7458 procedures. Proper specimen conditioning and sealing, calibrated pres
Chemical Composition Analysis of Borosilicate Glass 3.3
2026-11-10Chemical composition analysis of borosilicate glass 3.3 verifies the SiO₂–B₂O₃ balance, alkali content and trace oxides against specification. HF digestion feeds ICP-OES, borate fusion feeds XRF, and gravimetric or titrimetric wet chemistry settles d
ISO 3585 Borosilicate Glass 3.3 Testing: Composition
2026-11-10ISO 3585 composition testing verifies that a melt is true borosilicate glass 3.3. Samples are cleaned, ground and either fused into lithium borate beads for XRF or digested with hydrofluoric acid for ICP-OES. XRF quantifies the major oxides, while IC
ISO 15378 Compliance for Pharmaceutical Packaging: Key
2026-11-10ISO 15378 compliance for pharmaceutical packaging links a GMP-based quality management system to laboratory evidence across glass, elastomer, plastic, and aluminum primary packaging. The key elements are material qualification, extractables and leach
Extractables and Leachables (E&L) Testing for
2026-11-10Extractables and leachables (E&L) testing identifies and quantifies chemical migrants from pharmaceutical packaging materials and container closure systems. Controlled extraction with graded solvents generates an extractables profile analyzed by GC-M
Pharmaceutical Packaging Testing: Methods, Standards, and
2026-11-10Pharmaceutical packaging testing combines container closure integrity methods such as vacuum decay and tracer gas detection, extractables and leachables analysis by GC-MS, LC-MS, and ICP-MS, permeation measurement for water vapor and oxygen, and micr
δ13C Isotope Analysis Services: Applications from Food
2026-11-10δ13C isotope analysis determines the 13C/12C ratio of foods and their constituents on the VPDB scale, using EA-IRMS for bulk signatures and GC-C-IRMS for compound-specific values such as vanillin or ethanol. Services cover matrix preparation, calibra
Tracing Water Sources with Isotope Ratio Mass Spectrometry
2026-11-10Isotope ratio mass spectrometry traces water origin by measuring δ²H and δ¹⁸O on the VSMOW-SLAP scale. Reliable tracing depends on sealed, headspace-free sampling, continuous-flow measurement by CO₂ equilibration or high-temperature pyrolysis, two-po
Isotope Ratio Mass Spectrometer (IRMS): How It Works and
2026-11-09The isotope ratio mass spectrometer (IRMS) measures stable isotope ratios of light elements with sub-per mil repeatability. Samples are prepared as combustion or pyrolysis gases and measured by EA-IRMS for bulk signatures or GC-IRMS for compound-spec
Stable Isotope Testing for Geographic Origin Traceability
2026-11-09Stable isotope testing verifies geographic origin by measuring isotope ratios such as δ13C, δ15N, δ2H, δ18O, δ34S, and ⁸⁷Sr/⁸⁶Sr in food and agricultural products. Samples are analyzed by IRMS or GC/C-IRMS with calibration against international refer
δ13C Carbon Isotope Analysis by IRMS: Sample Requirements
2026-11-09δ13C analysis by IRMS converts sample carbon quantitatively to CO2, measures the 13C/12C ratio by mass spectrometry, and reports a delta value on the VPDB scale. Reliable results require dried, homogenized milligram aliquots, contamination-free colle
Isotope Ratio Mass Spectrometry (IRMS): How It Works and
2026-11-09IRMS measures stable isotope ratios (C, N, H, O, S) in gases produced by combustion or pyrolysis, reporting delta values against international standards. This article covers the measurement principle, sample preparation, instrument workflow, precisio
Dishwasher Resistance Testing for Plastics: Stress
2026-11-09Dishwasher resistance testing for plastics applies coupled thermal, chemical, and mechanical stress through repeated machine-wash cycles. Specimens are conditioned, washed in a standard domestic dishwasher with defined detergent and water hardness, t
Chemical Resistance Testing with Dishwasher Detergents
2026-11-09Chemical resistance testing with dishwasher detergents exposes finished specimens to alkaline detergent solutions or full wash cycles, then grades staining, whitening, corrosion, and coating adhesion alongside instrumental color, gloss, and mass chan
ISO 6421 Tableware Dishwasher Resistance Testing: Assessing
2026-11-09ISO 6421 dishwasher resistance testing subjects ceramic, glass, and decorated tableware to repeated standard wash cycles with controlled detergent, rinse agent, water hardness, and temperature. Specimens are inspected at staged intervals against unwa
Dishwasher-Safe Testing for Coatings and Finishes: Ensuring
2026-11-09Dishwasher-safe testing evaluates whether coatings and finishes survive repeated machine washing. Specimens representing production parts undergo accelerated dishwasher cycling with hot alkaline detergent, spray impingement, and thermal stress, inspe
EN 12875 Dishwashing Resistance Testing: Test Cycles
2026-11-09EN 12875 evaluates the resistance of tableware, cutlery, hollowware, and coated articles to repeated machine dishwashing. Standardized cycles combine hot alkaline detergent, spray impingement, thermal shock, and drying, executed in a reference machin
Dishwasher Resistance Testing: Methods, Standards, and How
2026-11-09Dishwasher resistance testing verifies whether tableware, coatings, plastics, and decorated articles withstand repeated hot alkaline washing cycles. Standardized machine-washing procedures with defined detergent, water hardness, and temperature repro
δ13C Carbon Isotope Ratio Analysis: Method, Standards and
2026-11-08δ13C carbon isotope ratio analysis by EA-IRMS or GC-IRMS measures the carbon-12/carbon-13 ratio against the VPDB reference, supporting food authenticity, adulterant detection, and origin verification. Samples are combusted or chromatographically reso
How Much Does IRMS Analysis Cost? Pricing, Sample
2026-11-08IRMS analysis cost is built from the isotope systems measured, sample count, matrix complexity, preparation needs, turnaround, and reporting depth. Single-isotope batch work sits at the lower end; multi-isotope or compound-specific profiling costs mo
IRMS Testing Services: How Isotope Ratio Mass Spectrometry
2026-11-08IRMS testing measures stable isotope ratios (δ13C, δ15N, δ18O, δD, δ34S) to verify food authenticity, geographic origin, and ingredient claims. Samples are analyzed by EA-IRMS for bulk solids and liquids, or by GC-IRMS and LC-IRMS for compound-specif
Send Us a Message
Fill out the form below and we'll respond within 24 hours.
Our Locations
Business Hours
ISO 17025 Accredited
All testing performed under rigorous quality management.