steel chemical composition testing
2026-11-18Steel chemical composition testing quantifies carbon, alloying, residual, and trace elements in steel using spark OES, ICP-OES, and combustion infrared analysis. Proper sampling and surface or dissolution preparation precede analysis; performance is
steel UV aging testing
2026-11-18Steel UV aging testing exposes coated steel specimens to cyclic ultraviolet light and condensation in fluorescent-UV or xenon-arc chambers, accelerating photo-oxidation of paints, powder coatings, and linings. Gloss retention, color difference, chalk
steel accelerated aging testing
2026-11-18Steel accelerated aging testing compresses years of service exposure into short laboratory cycles using thermal aging, humid heat, salt spray, cyclic corrosion, and strain aging. Specimens are weighed, exposed, then evaluated by mass loss, microscopy
steel thermal cycling testing
2026-11-18Steel thermal cycling testing exposes machined steel specimens to programmed heating and cooling cycles, then evaluates residual tensile properties, hardness, dimensional change, cracking, and microstructure against baseline specimens. Key controlled
steel humidity testing
2026-11-18Steel humidity testing exposes prepared steel specimens to controlled moist climates in calibrated chambers, following standards such as ISO 6270-2, ASTM D2247 and ASTM D4585. It measures rust grades, blistering, mass loss and time to failure against
steel flexural testing
2026-11-18Steel flexural testing measures how steel specimens resist transverse bending, using three-point loading for routine screening and four-point loading where constant bending moment is required. Key outputs are flexural strength, mid-span deflection, a
steel tensile testing
2026-11-18Steel tensile testing pulls a standardised specimen to fracture in a calibrated universal testing machine to determine yield strength, tensile strength, elongation and reduction of area. This article covers testing principles, specimen preparation an
New major investments in the Ports of Antwerp and Rotterdam
2026-11-17Testing for the Antwerp and Rotterdam port investments spans water and sediment sampling, dredged material analysis by GC-MS and ICP-MS, spectrophotometric heavy metal and PAH screening, ecotoxicity bioassays against acceptance thresholds, and PCR-ba
The Whole Product Package Testing
2026-11-17Whole product package testing evaluates the packaged item as delivered, covering seal integrity, drop, vibration, compression, closure performance, and chemical compatibility. This article outlines sample preparation and conditioning, deterministic a
Making a Declaration of Conformity for CE Marking in
2026-11-17A Declaration of Conformity for CE marking is drafted only after the applicable directives are identified, the technical file is assembled, and testing is completed by an accredited laboratory against the cited harmonised standards. The manufacturer
A Closer Look: Electrical Safety for 2013 - Part II Testing
2026-11-17Electrical safety testing for 2013 - Part II verifies products through three core methods: dielectric strength, protective earth bond, and leakage current measurement under normal and single-fault conditions. This article explains applicable standard
CPSC Testing and Certification Rule
2026-11-17The CPSC Testing and Certification Rule requires children's products to be tested by a CPSC-accepted laboratory before a Children's Product Certificate can be issued. Compliance is demonstrated per component material using ICP-OES for total lead, GC-
Certification to UL 2202 - Part II Testing
2026-11-17UL 2202 Part II testing verifies the safety of battery chargers for electric vehicles through dielectric withstand, leakage current, and protective bonding continuity measurements, followed by humidity conditioning and abnormal fault testing. This ar
Deadline Approaching: Washington State Children’s Safe
2026-11-17Washington State Children's Safe Products Act testing verifies whether children's products contain chemicals of high concern to children above practical quantitation limits. The workflow covers CHCC scoping, CPSC-based sample preparation and extracti
VOC Regulations in Canada are Changing Testing
2026-11-17Canadian VOC regulations are tightening limits on both formulation content and emissions, changing how testing is scoped and reported. This article outlines the analytical principle, regulated parameters, sampling practice, GC-MS and headspace proced
Global Growth in the Lithium-ion Battery Industry
2026-11-17Testing for the growing lithium-ion battery industry spans material, cell, and system levels. Key methods include EIS for impedance behavior, GC-MS for electrolyte and gas analysis, and ICP-OES for elemental impurities. Performance is judged by capac
National Pollutant Releases Inventory Reporting Notice
2026-11-17The NPRI Reporting Notice obliges facilities meeting employee, activity, and substance-threshold criteria to file annual release and transfer data. Compliance depends on CAS-level substance screening, a defensible hierarchy of quantification methods,
A Closer Look: Techniques for Obtaining Glass Transition
2026-11-16Glass transition temperature (Tg) is obtained calorimetrically by DSC, mechanically by DMA, or dilatometrically by TMA. Accurate results require controlled specimen preparation and conditioning, documented heating rates, regular instrument calibratio
A Closer Look at How the European Directive RoHS2 Impacts
2026-11-16RoHS 2 restricts ten hazardous substances in electrical and electronic equipment sold in the EU. Compliance testing follows a defined workflow: disassembling products into homogeneous materials, screening lead, mercury, cadmium, chromium, and bromine
What You Should Know: Medical Device Manufacturer's
2026-11-16A medical device manufacturer's testing program spans raw materials, components, finished devices, and packaging. Core methods include GC-MS and HPLC for residues and extractables, ELISA and cytotoxicity assays for biological evaluation, bioburden an
Update: Publication of the Revised In-Commerce List Testing
2026-11-16Testing in support of the revised In-Commerce List publication centers on confirming the identity, purity, and impurity profile of listed substances in commerce. GC-MS handles volatile, thermally stable compounds; HPLC with UV or MS detection covers
Mixing, Blending and Formulating: Salt does happen! Testing
2026-11-16Salt testing for mixed, blended and formulated products measures chloride or sodium via titration, ion chromatography or spectroscopy, using representative composite sampling and hot-water extraction. Homogeneity is judged from relative standard devi
What is a Medical Device? Testing
2026-11-16Medical Device Testing evaluates instruments, implants, software, and diagnostic products against electrical safety, EMC, biocompatibility, performance, and packaging standards under frameworks such as IEC 60601, ISO 10993, and ISO 11607. Test scope
Safer Products Save Lives™ Testing
2026-11-16Safer Products Save Lives™ Testing verifies chemical, microbiological, physical, and label safety across foods, agricultural goods, and consumer articles. An accredited laboratory applies HPLC, GC-MS, ELISA, PCR, and spectrophotometry within a contro
Safer Products & the Competitive Code Evaluation Market
2026-11-16Code evaluation for safer products examines embedded firmware and application code through combined static review and dynamic attack simulation. Laboratories assess vulnerability density, authentication resistance, and post-attack stability, then jud
Send Us a Message
Fill out the form below and we'll respond within 24 hours.
Our Locations
Business Hours
ISO 17025 Accredited
All testing performed under rigorous quality management.